Safety Enhancement of Elevator Based on Revised Building Standards Act

Abstract of amended Building Standards Law enforced on September 28th, 2009 is to enhance safety by means of three items mentioned below.

1. Obligation of Installing of Door Opening Running Protection Device [Relatd to Article 29, 10-3-1 of Example of Construction]

It is obliged to install a safety device which stops cages automatically in case where cages go up and down before all entrance doors of cages and hoistway shut due to malfunctions of drives or control devices of elevators. Protection device to prevent open door travel is required to be approved by Minister of Land, Infrastructure and Transport.

Door Opening Running Protection Device(UCMP)

(1) Door Opening Running Judgiment Device Board
When one of braking systems or control circuits fails, an independent circuit detects open door travel and stops cages.

(2) Duplication of Control Device
・Rope Type
Two mechanically independent mechanical brakes secure braking force.
・Hydraulic
Two mechanically independent hydraulic check valves secure braking force.

(3) Certain Distance Detector
It detects locations of elevators. Reduplication of switches is required.

(4) Cage Door Switch
A switch for forced separation mechanism or reduplication of switches is required.

(5) Platform Door Switch
It detects the open/close conditions of boarding place doors.
A switch for forced separation mechanism or reduplication of switches is required.


2. Obligation of Installing of Controlled Operation Device at the Time of Earthquake [Related to Enforcement Order Article 129, 10-3-2]

With regard to elevators it is obliged to install a safety device which enables cages to stop automatically in positions of entrance doors and enables doors of cages and hoistway to be opened in case where acceleration caused by earthquake and so on are detected.

Control operation device during earthquake is obliged to be consisted of following devices.

(1) Controled Operation at the Time of Earthquake(Sensor of P Wave and S Wave)
It detects preliminary tremor (P wave) or principal shock (S wave) and stops cages at the nearest floor and evacuates passengers.

(2) Reserve Electric Source(Automatic Reaching Floor Device at the Time of Power Failure or In-house Power Generation Resource)
Stand-by power source is required to prevent passengers from containment when power is down.

3. Enforcement of Safety Measure (Clarification of Standard) [Related to Enforcement Order Article 129, 4 to 10]

To enhance safety measure for elevators technical standards concerning safety of elevators stated that some structure of elevator cages, pivotal supporting parts, haistway, drives and controllers should adopt structural method determined by Minister of Land, Infrastructure and Transport.

Notification number Notification text Summary Remark
No. 703
The drive equipment and controller of the elevator is ensured not to be moved or felt by earthquake or any other shock Regulation to keep the drive equipment and controller of elevator not be moved or turned over by earthquake  
No. 1413
Define construction method of elevator or escalator with special structure or usage pattern Regulation of construction method of elevator (From No.1 to No. 10) or escalator (from No.1 to No.3) with special structure or usage pattern At Notification No 859, partial revision of notification No 1413
Control combination of special structure
No. 1446
Set standards of wall or enclosure or entrance door so that there is no possibility that people or object outside of hoistway of parcel exclusive used elevator to touch the cage or counterweight
Define structure of the hoistway of parcel exclusive used elevator
(No deformation is more than 15mm in case of a force of 300N on the surface of 5 ㎠ strength of the door and hoistway wall,
door gap below 6mm , glass applicable conditions of the wall, door)
Some of the content are enforced from September 28, 2010
No. 1447
Set standard of locking device of door entrance of the elevator shaft so that there is no risk of people or objects outside hoistway into the hoistway Regulation of the locking device of the entrance door of elevator shaft  
No. 1454
Define standard of wall or enclosure or entrance door so that there is no possibility of people or objects outside of the hoistway to touch cage or counterweight Define structure of elevator hoistway
(No deformation is more than 15mm in case of a force of 300N on the surface of 5 ㎠ strength of the door and hoistway wall,
door gap below 6mm, Door closing force below 150N, glass applicable conditions of the wall, door)
Some of the content are enforced from September 28, 2010
No. 1455
Set standard of the structure of each part to assure the safety against the impact by person or object inside cage and the standard of cage wall or enclosure or entrance door so that there is no possibility that people or object inside cage to touch object outside cage.
Regulation such as construction of case of elevator
(No deformation is more than 15mm in case of a force of 300N on the surface of 5 ㎠ strength of the door and cage wall,
cage floor lighting more than 50 lux, cage ceiling height more than 2m, door gap below 8mm, reversing device of the door, door closing force below 150Nglass applicable conditions of the wall, door)
Some of the content are enforced from September 28, 2010
No. 1461
Define style of document verifying the confirmatory test is taken place according to guideline related to confirmation examination. Regulation of additional contents of the confirmation request books
(Add position and structure diagram of maintenance and inspection contents and main support portion)
Connection notification No 885
No. 1469
Definition of structure method of elevator controller Regulation related to elevation control of elevator and floor matching control  
No. 1494
Define the structure method so that there is no posibility that junction as hinged joint structure is deviated by earthquake or any other shock Regulation of the major structural part of the elevator  
No. 1495
Measures prescribed by Minister of Land, Infrastructure and Transport; Building Standard Law Enforcement Order Article 129 Seven fifth issue of I (2)
Regulation of structure of elevator hoistway (Structure to prevent catching of ropes, cables during earthquake)  
No. 1498
Define structure method of elevator using pulley to hang the cage so that there is no possibility the cord is out of pulley by earthquake or any other shock The regulation for earthquake response of the major structural part of the elevator.
(Structure to latch the ope of pulley part)
 
No. 1536
Detect the acceleration and the relavant acceleration caused by earthquake and other impacts which is defined by Land, Infrastructure and Transport Minister, automatically stops the cage at the position of the door entrance of hoistway, and open the door entrance of the relavant cage and the door entrance of hoistway, or construct device so that people inside cage can ooen the door.
Regulation of the details of the installation required of control driving device during earthquake (control operation during earthquake, installation position and methods of the sensor, the operation after sensing the acceleration, the display of the control operation, standby power supply for operating in the event of a power failure)  

With regard to inquiry about the amended Building Standards Law or periodical inspection and maintenance checkup for elevators please refer to this.



All information provided in this home page and all copyright of logo marks and trademarks of the company, images and videos belong to DAIKO Co. Ltd.